The HD2114.0, HD2134.0, HD2164.0 micromanometers, the HD2114B.0 barometer, and the corresponding HD2114.2, HD2134.2, HD2164.2 and HD2114B.2 models with datalogger function. They are portable instruments with a large LCD display. They perform measurements of absolute, relative and differential pressure, and temperature.

Pressure is measured using an internal differential module that compares the atmosphere with bottom of a fixed scale. With the PP471 module acting as an interface, the instrument can use all the TP704 and TP705 series Delta Ohm probes to perform the measurements. The HD2114B.0 and HD2114B.2 internal module measures the barometric pressure. The temperature is detected using immersion, penetration, contact or air probes, with SICRAM module or direct 4-wire probes. The sensor can be a Pt100, Pt1000 or Ni1000. The temperature probes are fitted with a SICRAM module, with the factory calibration settings already being memorized inside. On being turned on the instrument automatically detects these settings.

The HD2114.2, HD2134.2, HD2164.2 and HD2114B.2 instruments are dataloggers. They memorize up to 36,000 samples, which can be transferred from the instrument connected to a PC via the RS232C serial port or USB 2.0 port.

The storing interval, printing, and baud rate can be configured using the menu. The HD2114.2, HD2134.2, HD2164.2 and HD2114B.2 instruments can transfer via the RS232C serial port the acquired measurements to a PC or to a portable printer in real time.

The Max, Min and Avg function calculates the maximum, minimum or average values. The Peak function can be activated with external probes connected to the module PP471 and detects the presence of pressure peaks. Other functions include the relative measurement REL, the HOLD function, and the automatic turning off which can also be disabled. The instruments have IP66 protection degree.  

  • Part Number: HD2114B.0
  • Sensor: Built-in Barometric Sensor (600-1100 mbar)
  • Data Logger: Not included
  • Full scale 600..1100 mbar
  • Maximum overpressure 3 bar
  • Resolution  0.1 mbar
  • Accuracy @23°C ±0.3 mbar
  • Working temperature 0…60 °C
  • Connection quick couplings Ø5 mm
  • Compensation temperature 0…60 °C
  • Drift on zero  ±0.3% f.s
  • Drift on span±0.3% f.s
  • Fluid contacting the membrane non corrosive air and gas

  • Full scale: 600..1100 mbar
  • Maximum overpressure: 3 bar
  • Resolution : 0.1 mbar
  • Accuracy @23°C:  ±0.3 mbar
  • Working temperature:  
  • Connection quick couplings: Ø5 mm
  • Compensation temperature: 0…60 °C
  • Drift on zero : ±0.3% f.s
  • Drift on span: ±0.3% f.s
  • Fluid contacting the membrane: non corrosive air and gas
  • Measurement of temperature:
  • Pt100 measurement range: -200…+650 °C
  • Pt1000 measurement range: -200…+650 °C
  • Resolution: 0.1 °C
  • Instrument accuracy: ±0.1 °C
  • Drift after 1 year: 0.1 °C/year
  • Measuring unit: °C - °F - Pa - hPa - kPa - mbar - bar- atm mmHg - mmH2O - kgf/cm2 - PSI - inchHg
  • Measured values storage - models HD21...4.2:
  • Tipe: 2000 pages containing 18 samples each
  • Quantity: 36000 samples (pressure - temperature)
  • Storage interval: 1,5,10,15,30 s;  1,2,5,10,15,20,30 min;  1 hour
  • Security of stored data: Unlimited, independent of battery charge conditions
  • Power supply: Batteries 4 x 1.5V type AA batteries
  • Autonomy: 200 hours with 1800mAh alkaline batteries
  • Current consumption with instrument off: 20 μA
  • Mains - models HD21...4.2: Output mains adapter 12 Vdc / 1000 mA
  • Serial interface RS232C - models HD21...4.2:
  • Type: RS232C electrically isolated
  • Baud rate: Can be set from 1200 to 38400 baud
  • Data bit: 8
  • Parity: None
  • Stop bit: 1
  • Flow Control: Xon/Xoff
  • USB interface - models HD21...4.2:
  • Type: 1.1 - 2.0 electrically isolated
  • Connections:
  • Input modules for the probes: 2 quick couplings Ø 5 mm
  • Serial interface models HD21...4.2: 8-pole MiniDin connector
  • USB interface models HD21...4.2: Mini USB type B connector
  • Mains adapter - models HD21...4.2: 2-pole connector (positive at centre)
  • Operating conditions:
  • Working temperature: -5 … 50 °C
  • Storage temperature: -25 … 65 °C
  • Working relative humidity: 0…90% RH without condensation
  • Protection degree: IP66
  • General characteristics:
  • Dimensions (Length x Width x Height): 185 x 90 x 40 mm
  • Weight: 470 g (complete with batteries)
  • Materials: ABS, rubber
  • Display: 2 rows 4½ digits plus symbols
  • Visible area: 52x42 mm
  • Time: Date and time Real time; Accuracy 1 min/month max drift

  • (1) HD2114B.0 Barometer-Manometer-Thermometer with built-in barometric sensor (600…1100 mbar)
  • (4) 1.5V alkaline batteries
  • (1) Operating manual
  • (1) Case
  • NOTE: Other probes and PP471 module have to be ordered separately